Chapter 21
Skill 21-5 Placing a Patient on a Full-Body Vacuum Mattress(CPI) = Critical Performance Indicator — failing any CPI is an automatic failure. Unless noted, every skill begins with: determine the scene is safe, initiate standard precautions, introduce self and obtain permission to treat/help.
0 of 14 steps Reset
Lay the mattress flat near the patient, head end at the patient's head. Open the valve until the mattress is soft and pliable. Smooth the mattress flat and level. Connect the pump. Choose the transfer method: for a logroll, partially evacuate until semi-rigid with beads evenly spread; for a scoop stretcher, skip partial evacuation. Move the patient onto the mattress, maintaining spinal alignment. If the mattress is partially rigid, open the valve until pliable again. Form "head blocks" on each side of the head near the shoulders (not over the top of the head); a second person holds the sides up to the hips while all air is evacuated. Secure chest, hips, and legs. Secure the head with medical tape; pad voids at the tops of the shoulders. Make the patient as comfortable as possible, then evacuate remaining air. Disconnect the pump and close/secure the valve. Reassess and adjust chest, hip, and leg straps. Check neurovascular status and recheck all straps before lifting. Practice it in these scenarios Source: Outdoor Emergency Care: A Patroller's Guide to Medical Care , 6th ed.